MAXI RAIN Control panel
MAXIRAIN
Electromechanical control panel ready for remote control for 4RMVE / 4RMG / 4RMG-D linear machine


Control panel for 4RMVE / 4RMG / 4RMG-D linear

Control panel adapted for simple and complex customer field from simple back and forth course, internal / external hippodrome course and even specific customer course that fit to the irrigated field
Complete, clear and simple human-machine interface
A lot of options available to start from a simple to a precision irrigation
Time and money saving thank to the mix of machine remote control tools and electromechanical panel
Many control panel finishing available
FIRST
FIRST
PREMIUM
PREMIUM
CONTROL PANEL BASIC COMMANDS :
CONTROL PANEL BASIC COMMANDS :
SPEED IN ROTATION MODE - 1% ACCURACY
SPEED IN ROTATION MODE - 1% ACCURACY
SPEED IN LINEAR MODE - 1% ACCURACY
SPEED IN LINEAR MODE - 1% ACCURACY
SPANS REALIGNMENT
SPANS REALIGNMENT
FORWARD DIRECTION
FORWARD DIRECTION
BACKWARD DIRECTION
BACKWARD DIRECTION
AUTOMATIC INVERSION
AUTOMATIC INVERSION
STOP
STOP
START - WET MODE
START - WET MODE
START - DRY MODE
START - DRY MODE
AUTOMATIC/MANUAL COURSE
AUTOMATIC/MANUAL COURSE
START ROTATION MODE
START ROTATION MODE
START LINEAR MODE
START LINEAR MODE
EXTERNAL/INTERNAL ROTATION CONFIGURATION
EXTERNAL/INTERNAL ROTATION CONFIGURATION
CONTROL PANEL FINISH :
CONTROL PANEL FINISH :
POLYESTER
POLYESTER
METAL
METAL
INOX
INOX
MACHINE DIAMETER :
MACHINE DIAMETER :
141
141
168
168
193
193
COURSE TYPE :
COURSE TYPE :
BACK AND FORTH & EXTERNAL/INTERNAL ROTATION
BACK AND FORTH & EXTERNAL/INTERNAL ROTATION
SPECIFIC COURSE
SPECIFIC COURSE
REMOTE CONTROL DEVICES FOR ELECTROMECHANICAL CONTROL PANEL :
REMOTE CONTROL DEVICES FOR ELECTROMECHANICAL CONTROL PANEL :
RAINDRIVE
RAINDRIVE
RAINLOC
RAINLOC
ELECTROMECHANICAL OPTIONS :
ELECTROMECHANICAL OPTIONS :
BOOSTER PUMP
BOOSTER PUMP
INLET VALVES
INLET VALVES
HYDRANT STOP
HYDRANT STOP
DELAYED INVERSION TIMER
DELAYED INVERSION TIMER
DELAYED START TIMER
DELAYED START TIMER
ARRIVAL TIMER BEFORE ROTATION
ARRIVAL TIMER BEFORE ROTATION
AUTOMATIC INVERSION WITH INVERSION DEVICE ON TOWER
AUTOMATIC INVERSION WITH INVERSION DEVICE ON TOWER
DOUBLE SPEED TIMER - FORWARD/BACKWARD
DOUBLE SPEED TIMER - FORWARD/BACKWARD
1 ENDGUN STOP IN ROTATION MODE
1 ENDGUN STOP IN ROTATION MODE
1 ENDGUN STOP IN LINEAR MODE
1 ENDGUN STOP IN LINEAR MODE
2 OR MORE ENDGUN STOPS IN ROTATION MODE
2 OR MORE ENDGUN STOPS IN ROTATION MODE
2 OR MORE ENDGUN STOPS IN LINEAR MODE
2 OR MORE ENDGUN STOPS IN LINEAR MODE
FERTIGATION - PUMP AND MIXER
FERTIGATION - PUMP AND MIXER
GENERATOR SECURITY STOP
GENERATOR SECURITY STOP
SURGE PROTECTOR
SURGE PROTECTOR
PHASE MISSING CONTROL / POWER OUTAGE
PHASE MISSING CONTROL / POWER OUTAGE
3 POSITIONS SWITCH
3 POSITIONS SWITCH
2 POSITIONS SWITCH
2 POSITIONS SWITCH
VOLTAGE REGULATOR TRANSFORMER
VOLTAGE REGULATOR TRANSFORMER
TRANSFORMER 460VAC-115VAC
TRANSFORMER 460VAC-115VAC
DEFAULT MODULE FOR SPAN NUMBER INDICATION OR ELECTROMECHANICAL DEFAULT
DEFAULT MODULE FOR SPAN NUMBER INDICATION OR ELECTROMECHANICAL DEFAULT
OVERWATERING SYSTEM
OVERWATERING SYSTEM
LINEAR GUIDING SYSTEM - HOCKEY STICK TYPE OR AERIAL CABLE
LINEAR GUIDING SYSTEM - HOCKEY STICK TYPE OR AERIAL CABLE
LINEAR GUIDING SYSTEM - UNDERGROUND CABLE
LINEAR GUIDING SYSTEM - UNDERGROUND CABLE
FOLDABLE OVERHANG
FOLDABLE OVERHANG
STOP IN LINE
STOP IN LINE
SPECIFIC COMPONENT FOR CONTROL PANEL :
SPECIFIC COMPONENT FOR CONTROL PANEL :
DIFFERENTIAL SWITCH
DIFFERENTIAL SWITCH
HOUR METER
HOUR METER
SECURITY INDICATOR
SECURITY INDICATOR
VOLTMETER
VOLTMETER